1) What is a non-shrink grout?
2) What kind of work is non-shrink grout suitable for?
3) What is epoxy grout and what kind of work is epoxy grout suitable for?
4) What is the suitable material to be used for filling block-out of pipe penetrations? why?
5) What are sealants?
6) How to close or seal the gap between the existing and new building?
7) What is the suitable waterproof material to be used for coating inside of reinforced concrete tank?
8) What is a suitable waterproof material to be used for concrete roof of building?
9) How to repair the water leakage of basement?
10) Why is the price for epoxy floors very expensive?
11) We used epoxy flooring in our factory before but found that it was easily damaged hence did not last long?
12) Is epoxy toxic?
13) Do you give a warrantee?
14) Can epoxy flooring be applied to moist concrete surfaces and is it resistant to acids and alkali?
15) I would like to use an epoxy flooring material that is easy to apply, but we need technical support to instruct our workers at job site. Is this  possible?
16) The advantage of epoxy flooring depends on the thickness, right?
17) Are there any admixtures suitable for high volume of fly ash for normal concrete?
18) How can I become a retail outlet for MYK Schomburg’s products?
19) How can I fix my leaking roof ?
20) Who is a responsible personnel to contact for waterproofing recommendations?
21) Which of our range products can stop a water leakage ?
22) Why should one use MYK Crete RN Repair Mortar instead of cement and sand?
23) How does retarding admixture effect to fly ash concrete?
24) How to solve the problem of fly ash on surface concrete according to bleeding?
25) How to use super plasticizer admixtures in correct way?
26) How to inspect the admixture properties?
27) Can we use the longer keeping of admixtures in drum more than 1 year?
28) How to accelerate concrete with short period e.g. concrete slip form or fast set owing to the limitation of the amount of formwork?
29) How to choose a proper form release agent with concrete?
30) Is waterproof admixture in normal concrete resistant to sulfate attack?
31) Are there different among cement in each brand and admixtures?
   
1. What is a non-shrink grout?
Non-shrink grout is special pre-mixed cement with shrinkage compensation additive. It has a good flowability and high compressive strength after being mixed with water.
 
   
2. What kind of work is non-shrink grout suitable for?
Non-shrink grout is suitable for grouting of machine base plate, bridge girder and for repairing of concrete structures etc.
 
   
3. What is epoxy grout and what kind of work is epoxy grout suitable for?
Epoxy grout is special pre-mixed of epoxy with selected aggregates and additives which resulting in good flowability and high early compressive strength gain. Epoxy grout is suitable for grouting of machine base plate with vibration, chemical resistance and for repairing works.
 
   
4. What is the suitable material to be used for filling block-out of pipe penetrations? why?
Non-shrink grout is a suitable material to be used for filling block-out of pipe penetrations because it is able to pour into the formwork easily and it does not shrink after setting.
 
   
5. What are sealants?
Sealants are the flexible materials to be used for sealing expansion joints, Construction joints gaps or cracks to protect concrete structure from moisture, gases, chemical substances or any contaminants
 
   
6. How to close or seal the gap between the existing and new building?
The suitable system is Myk Seal PS. This system will withstand a large movement because of high elongation property and it can also protect leakage of the joint
 
   
7. What is the suitable waterproof material to be used for coating inside of reinforced concrete tank?
The waterproof material should be a cementitious base which should be penetratable and should be of crystalline nature such as MYK Aquafin IC.
 
   
8. What is a suitable waterproof material to be used for concrete roof of building?
The waterproof material should be a modified acrylic waterproof membrane. It has an excellent adhesion to substrate and it can be resistant to weather and UV. It can be available in various shades. MYK Aquafin 2K/M can be used successfully in these cases.
 
   
9. How to repair the water leakage of basement?
The polyurethane foam injection is suitable method to repair using high pressure. The polyurethane foam will expand when contact with water stopping water leakage immediately. The product is MYK Aquafin P1 & P4
 
 
10. Why is the price for epoxy floors very expensive?
The basic raw materials for the manufacturing are been imported from Germany (Mother Company) and also due to there higher end properties over the concrete would obviously demand more price. The price of epoxy floors depends on performance criteria of the flooring system and can vary from Rs. 500.00 to Rs. 2000.00 depending on the specific requirements and end use. For very high specifications the rate would be even higher. Hence a thorough inspection of the new or existing floor to be taken up and also need to understand the end use or the requirements based on which the epoxy flooring system will be recommended.
 
   
11. We used epoxy flooring in our factory before but found that it was easily damaged hence did not last long?
This usually happens when the specification for the flooring system does not take the in service conditions of the floor into account. If you are interested in an industrial flooring proposal please mail your contact details and location map to us, so we can jointly inspect the area and prepare a tailor made proposal for you.
 
   
12. Is epoxy toxic?
In principal when handling epoxy based materials it is recommended to wear protective clothing because in a liquid state the material can be harmful in case of prolonged exposure. For more details please consult the pertaining Safety Data Sheet.
 
   
13. Do you give a warrantee?
MYK Schomburg warrants the performance of our products as stated in pertaining data sheets. The application warranty is the responsible of the chosen applicator
 
   
14. Can epoxy flooring be applied to moist concrete surfaces and is it resistant to acids and alkali?
MYK Schomburg has developed Moisture Insensitive primers suitable for application on moist concrete also acting as a permanent moisture barrier to enable subsequent epoxy topcoat application. Epoxy based flooring materials are able to resist many chemicals, details refers pertaining technical data sheets. The specifications keep changing as per the requirements or the end use.
 
   
15. I would like to use an epoxy flooring material that is easy to apply, but we need technical support to instruct our workers at job site. Is this possible?
Yes, please do not hesitate to contact us on our contact no. we shall attend your immediately.
 
   
16. The advantage of epoxy flooring depends on the thickness, right?

The thickness is governed by the mechanical and chemical exposure, i.e. for foot traffic and light trolleys 0.5 mm to 1.0 mm thickness would be sufficient. With increasing load of vehicles and frequency of traffic exposure the thickness increases.

 
 
17. Are there any admixtures suitable for high volume of fly ash for normal concrete?
Fly ash generally behaves chemical reactive slower than cement hydrated particular in high volume. So fly ash in concrete will affect dramatically to longer time of setting. Specific admixture should have ability to water reduction from medium to high level and less affect to set time. In generally mid-range types recommend using rate at 300 - 600 ml per 100 kg of cementitious content. By the way, using fly ash concrete should keep much consideration how optimum percentage of fly ash is in one cubic meter. It will better approach if concrete design suits for concerned application base rather than cost-advantage only.
 
   
18. How can I become a retail outlet for MYK Schomburg’s products?
You may directly contact us on our contact no.’s as mentioned in the contact us section.
 
   
19. How can I fix my leaking roof ?
As MYK Schomburg has various water proofing products tailored to the type of water infiltration, ask questions to ascertain the cause of the leakage, i.e. Cracks in flat roof, Joint failure, penetration, etc. Derived from the answers you may select a suitable product and explain its application.
 
   
20. Who is a responsible personnel to contact for waterproofing recommendations?
You may recommend a specialized contractor with experience in use of MYK Schomburg products, or contact our customer service department for advises
 
   
21. Which of our range products can stop a water leakage ?
It is depending on the type of leakage. The suitable product may be an admixture, cementitious or acrylic lining, flexible sealant, etc.
 
   
22. Why should one use MYK Crete RN Repair Mortar instead of cement and sand?
MYK Crete RN Repair Mortar is less prone to cracking, shows a much improved bond to concrete and mortar and contains a corrosion inhibitor.
 
   
23. How does retarding admixture effect to fly ash concrete?
All admixtures containing retarding absolutely affect to concrete properties particular in setting time, and also others physical properties such a bleeding rate and segregation. Most retarding admixture will affect to longer set of cement hydrated depending on dosage rate. Particular in high volume of fly ash in concrete is significantly much affect both longer set and risk of bleeding occurrence. So users should aware of correct dosage to fly ash concrete. By theoretically, retarding admixtures are recommend
 
   
24. How to solve the problem of fly ash on surface concrete according to bleeding?
Firstly, the engineer should inspect the properties of aggregate whether comply with correct standard or not. Then he should consider to production process, including with type and dosage rate of admixture as correct. Apart form internal inspection, he should observe how the contractors do in concrete placing in correct way. By the way if all things are done ready, that problem still is occurred. Secondly, it must be solved at that time. In generally bleeding rate will be happening within first 2-3 hours which if it happen too much bleeding, we are necessary to move the excess water out. Then it might use cement on top of concrete or use hardening admixture spray on surface of concrete. Both of them will benefit if it use in proper time particular in before concrete set. Finally, then please do not curing concrete surface with water or curing compound in order to protect shrinkage crack and better strength development.
 
 
25. How to use super plasticizer admixtures in correct way?
Before using superplasticizer admixtures, user should understand 2-3 relevant factors of them. Firstly, in mixing process normally superplasticizer should put in after mixing water into cement in few seconds. In practically, it might not able to control under saying. The different outcomes between mixing admixture with water and after water mixing probably differ slightly but in significantly. Secondly, mixing time should take at least 90 seconds per batch in order to get better homogeneity. Finally, how to teach operation level to understand and practice in correct way, also transfer to contractors later
 
   
26. How to inspect the admixture properties?
There are generally 3 methods to inspect the properties of chemical admixtures. The first method is called ?Physical properties? e.g. specific gravity, solid content, pH, viscosity and physical properties. The second method is called ? Concrete properties? e.g. percentage of water reduction, strength index, time of set. The last method is called ? Chemical properties? or chemical composition analysis which it has limit of Thai institution both personal and equipment aspect, so most of them are necessary to inspect aboard.
 
   
27. Can we use the longer keeping of admixtures in drum more than 1 year?
In case of old stock, we recommend that should test it before using under the product specification and comply with ASTM in concrete properties
 
   
28. How to accelerate concrete with short period e.g. concrete slip form or fast set owing to the limitation of the amount of formwork?
It can adopt cement type III for developing early strength or use admixtures type F without retarding effect. Then concrete should minimize water-to-cement ratio or control lower slump. However, there is the another option to use hardening accelerator admixture type combination with superplasticizer to rapid set time of concrete
 
   
29. How to choose a proper form release agent with concrete?
There are major two kinds of form release agent: water base and solvent-oil base. Water-base type can apply for concrete casting in roof-protection factory. There are two types of water base: ready-to-use and diluted with water in concentration. The another type is solvent oil-base that can be applied both in-door and out-door factory. The advantage of oil-base is against rain environment after applying on formwork. Moreover, some are blended with second-grade oil to reduce its cost
 
   
30. Is waterproof admixture in normal concrete resistant to sulfate attack?
Waterproofing admixture is normally designed for reducing water content by theoretically less than 0.45 of water-to-cement ratio. So, in case of either sulfate or chloride resistance concrete should be better considered to lower water content and use chemically reaction with pozzolan materials and superplasticizer admixture integrated in hydration in concrete
 
 
31. Are there different among cement in each brand and admixtures?
Each cement brands are slightly different in water consumption, set time, fineness, and strength index. So, admixture properties should compatible to each type or each brands. The important thing is whatever brand cement usage should apply for correct concrete application, mix designs, dosage rate and pozzolan materials
 

Quickly and easily calculate your consumption of our products.